Sign In | Join Free | My udpf.com |
|
Brand Name : Keramcontrols
Model Number : KWFS
Certification : CE
Place of Origin : China
MOQ : 10
Payment Terms : L/C, T/T
Supply Ability : 2000pics/month
Delivery Time : 7days
Packaging Details : Carton
Type of operation : On/Off,single-stage,micro switch
Output : SPDT 15(8A) 24/250VAC
Flow rates : See flow rate table
Housing protection : IP65
KWFS water flow switch is a device for automatic control and protection of water flow. When the water flow changes, the force generated by the water flow on the target makes the lever rotate and the control circuit close or open, thus achieving the purpose of automatic control. Water flow switch is widely used in the water system of water chiller and air conditioning engineering. It can ensure the safe and efficient operation of air conditioning system.
Control and monitor liquid flow of boilers, pumps, etc., of heating, cooling, and air conditioning equipment.
Features
● Flow control of water and normal media
● Renovated SPDT micro switch ensures the reliable switch function
●15(8A)250VAC switch rating
● IP65, class I enclosure
● Set point adjustable
● Stainless steel paddle
● Brass material
● Max. liquid temp 120℃
● Max working pressure 20Ba
Type of operation | On/Off,single-stage,micro switch |
Output | SPDT 15(8A) 24/250VAC |
Flow rates | See flow rate table |
Flow rate setting adjustment | Internal screw |
Sensing element | Paddle |
Liquid applications | Hot, chilled, well, pool and sea water,Brine or ethylene glycol |
Parts material in contact with fluid | Brass |
Paddle material | Stainless steel |
Liquid temperature | -20℃~120℃ |
Permissible ambient temperature | -40℃~85℃ |
Permissible ambient humidity | 10…90% RH, non-condensing |
Cable entry | M18 Fitting |
Housing | Fire Resistance ABS or PC |
Protection | IP65 |
Color | White |
Weight | 1.0Kg |
Types of Model
Model | Connection |
KWFS-1 | 1/2" -14 NPT |
KWFS-2 | 3/4" -14 NPT |
KWFS-3 | 1" -11½ NPT |
Line Pipe Size(in.) | 1 | 1-¼ | 1-½ | 2 | 2-¼ | 3 | 4 | 4Z | 5 | 5Z | 6 | 6Z | 8 | 8Z | |
Min.flow | Flow Increase | 4.2 | 5.8 | 7.5 | 13.7 | 17.6 | 27.5 | 64..7 | 35.2 | 125 | 57.01 | 190.0 | 74.0 | 374.7 | 204.7 |
Flow Decrease | 2.5 | 3.7 | 5.0 | 9.7 | 11.9 | 19 | 50.1 | 26.9 | 101.1 | 41.0 | 158.0 | 54.0 | 319.7 | 170.0 | |
Max.flow | Flow Increase | 9.2 | 13.3 | 17.6 | 26.9 | 30.8 | 50.2 | 127.6 | 81.0 | 245.0 | 118.0 | 374.7 | 144.0 | 759.5 | 415.0 |
Flow Decrease | 8.1 | 12.5 | 16.3 | 25.1 | 28.6 | 47.1 | 122.0 | 76.2 | 234.7 | 111.0 | 359.7 | 134.7 | 729.6 | 400.6 |
Note:
①For flow rates with suffix "Z", the 6 inch paddle must be installed.
②The flow rate unit of the above table is GPM (m /h)
The flow switch can be installed in every position far from elbows or throttlings, with arrow on flow direction. If pipe is vertical, recalibrate range to balance paddle weight. If the device is downwards mounted, take care to slags and apply it in a straight pipe that is far from filters,valves,etc.,with length at least 5 times the diameter of pipe upstream and downstream the unit.
Note:
The flow switch is factory calibrated at its minimum sensitivity.To increase the set valve,turn the adjustment screw clockwise.The cut-out valve must be ≥the minimum flow necessary to guarantee the protection of the plant.
Install Paddle | |
Pipe | NO. |
1" | 1 |
11/4" | 1 |
11/2" | 1 |
2" | 1,2 |
21/2" | 1,2 |
3" | 1,2,3 |
4" | 1,2,3 |
4"Z | 1,2,3,4 |
5" | 1,2,3 |
5"Z | 1,2,3,4 |
6" | 1,2,3 |
6"Z | 1,2,3,4 |
8" | 1,2,3 |
8"Z | 1,2,3,4 |
![]() |
IP65 SPDT Water Pump Liquid Flow Switch On Off Single Stage Images |